Home   -   Solutions & Products   -   Integrated PV + Storage + Charging + Generator Solutions

L418 Energy Storage and Charging Station

L418 Energy Storage and Charging Station
L418 Energy Storage and Charging Station
L418 Energy Storage and Charging Station
L418 Energy Storage and Charging Station

Cell Parameters

Rated Voltage and Capacity3.2V  314AhREPT PC-0B1-72174L4-BE
Voltage Range2.5V-3.65V
Rated C-Rate0.5P
Maximum C-Rate0.5P
Rated Life ≥6000 cycles @0.5C, 157ADischarge at constant current of 0.5C (A) to 2.5V, rest for 30 minutes, then proceed to the next cycle until the capacity decays to 80% of the nominal capacity

Pack Parameters

Rated Voltage166.4V
Voltage Range130-189.8
Rated Energy52.2496kwh
Grouping Method / Configuration1P52S

Battery Cluster Parameters

Rated Voltage665.6V
Voltage Range520-759.2V
Rated Energy208.99kwh
Grouping Method / Configuration1P208S
Number of PACKs4

Energy Storage System Parameters

Rated Voltage665.6VConsidering the operating voltage range of the constant power section of the power module, 4 PACKs are connected in series to form one cluster, and 2 clusters are connected in parallel
Voltage Range520-759.2V
Rated Energy417.98kWh
Grouping Method / Configuration2P208S
Number of PACKs8
Cooling MethodLiquid Cooling

AC Side Parameters

Replenishment Power40kW*2
Replenishment DurationApprox. 4.7hDOD based on 90%
Module Cooling MethodAir CoolingTentative, subject to actual selection
EfficiencyPeak Efficiency >97%
Input Voltage Range380V±15%
Input Frequency50/60 Hz
Power Factor0.99
Voltage System / Voltage Standard3-Phase + N + PE
Rated Voltage380V

Charging Parameters

DC-DC Module Configuration40kW*6
Rated Power289kWIncluding AC side power 80kW
Cooling MethodAir Cooling
EfficiencyPeak ≥0.97
Output Voltage Range200-1000VDC
Maximum Output Current per Gun375ALiquid cooling optional
Maximum Output Power per Gun289kWNon-liquid cooling
Power Distribution MethodDynamic Distribution
Number of Guns2

Others

Structural Dimensions (WDH)2.6m*1.1m*2.3mEstimated. The buyer expects it to be narrower (likely difficult)
IP Rating (Enclosure)IP54
Noise<75dBEstimated, to be measured
Operating Altitude≤2000m, derating above 2000m
Operating Humidity0-95%
Weight (kg)Approx. 4500kgEstimated
Fire Protection System Active Fire Protection Solution: Smoke/Temperature Detection + PACK-Level Fire Suppression + Fire Extinguisher
BMS (Battery Management System)Active/Passive Balancing, OptionalActive and passive are mutually exclusive and should be determined at the project initiation stage
PV Access / Photovoltaic AccessDC Coupling
DC ReplenishmentDC Gun CCS2 Replenishment, OptionalShould be determined at the project initiation stage
Target MarketOverseas Markets Compliant with EU CertificationSpecific national certifications are not included (e.g., Germany PTB)
CertificationCEIf specific certification bodies are required, please specify in advance